NICET ITFAS-Level-1 Exam Overview:
| Certification Vendor: | NICET |
| Exam Name: | Inspection and Testing of Fire Alarm Systems Level I |
| Exam Number: | ITFAS-Level-1 |
| Passing Score: | 500/700 |
| Exam Duration: | 110 minutes |
| Related Certifications: | NICET Inspection and Testing of Fire Alarm Systems Level II |
| Real Exam Qty: | 85 |
| Certificate Validity Period: | 3 years |
| Available Languages: | English |
| Exam Price: | USD 230 |
| Exam Format: | Multiple-choice, Multiple-select, Hotspot |
| Sample Questions: | NICET ITFAS-Level-1 Sample Questions |
| Exam Way: | Computer-based test (CBT) at Pearson VUE Testing Centers or online remote proctoring (OnVue). |
| Pre Condition: | Minimum of 6 months of experience in the inspection and testing of fire alarm and suppression interfaces. |
| Official Syllabus URL: | https://www.nicet.org/certification-programs/electrical-and-mechanical-systems/inspection-and-testing-of-fire-alarm-systems |
NICET ITFAS-Level-1 Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| Topic 1: Maintain Devices | 3-13% | - Clean devices as needed - Identify replacement devices as needed - Replace batteries as needed |
| Topic 2: Test Equipment | 24-34% | - Manually measure sensitivity of detectors (without accessing site-specific programming) - Test basic interfaces - Test control equipment and circuits - Test initiating devices and circuits - Test off-premises signaling equipment and circuits - Test notification appliances and circuits |
| Topic 3: Inspect Equipment | 24-34% | - Inspect notification appliances (e.g., horns, strobes, speakers) - Inspect control equipment (e.g., fire alarm control panels, power supplies) - Inspect basic interfaces - Inspect initiating devices (e.g., smoke detectors, heat detectors, manual pull stations) - Inspect off-premises signaling equipment |
| Topic 4: Plan and Coordinate Work | 7-17% | - Coordinate with the owner/building manager during inspection and testing - Determine the number, type, and location of devices to be inspected and/or tested - Restore the system - Issue notifications to applicable parties of testing and completion as needed - Identify and apply the appropriate inspection and testing requirements for the job - File documentation and reports - Identify findings and issue appropriate notifications to applicable parties |
NICET Inspection and Testing of Fire Alarm Systems Level I Sample Questions:
1. What is the inspection frequency of supervising station alarm system transmitters?
A) Monthly
B) Quarterly
C) Annually
D) Semiannually
2. Visible and audible trouble signals shall be indicated at which two of the following locations? (Choose two.)
A) Emergency command center
B) Fire department headquarters
C) Alarm company office
D) Fire alarm control unit
3. Which NFPA standard determines the testing of a carbon monoxide device or system?
A) 72
B) 101
C) 12
D) 70
4. Within a fire alarm control unit, what is the maximum delay in seconds for alarm system responses after the initiation device has been activated?
A) 10
B) 30
C) 60
D) 15
5. According to NFPA 72, manual fire alarm boxes shall be located within which distance of each exit doorway on each floor?
A) 6 feet (2.0 meters)
B) 5 feet (1.5 meters)
C) 16 feet (5.0 meters)
D) 33 feet (10.0 meters)
Solutions:
| Question # 1 Answer: B | Question # 2 Answer: A,D | Question # 3 Answer: A | Question # 4 Answer: B | Question # 5 Answer: B |